Gold Member Since 2016
Audited Supplier
Zhongshan Hiline Electronics Co., Ltd.

LED Power Supply, Meanwell IP67 Driver, Switching Mode Driver manufacturer / supplier in China, offering Original Meanwell Hlg-600h Series Single Output Waterproof IP67 LED Driver, Popular Hotel Lamp LED Wall Reading Light CREE 3W Dimmable, 3A in 16 Channels Art-Net Digital Controller and so on.

(/ )

Supplier Homepage Product LED driver Meanwell LED power supply Original Meanwell Hlg-600h Series Single Output Waterproof IP67 LED Driver

Original Meanwell Hlg-600h Series Single Output Waterproof IP67 LED Driver

FOB Price: US $9-19 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $9-19/ Piece
Get Latest Price
Port: Zhuhai, China
Production Capacity: 200 PCS/Week
Payment Terms: T/T, Western Union, Paypal

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: HLG-600H
  • Output Type: Single
  • Circuit Structure: PWM Controlled
  • Power Supply Mode: Constant Current Source
  • In-Out: Step-down Type
  • Pack Sealing Size: SMD
  • Size: 280*144*48.5mm
  • Transport Package: Paper Carton
  • Origin: Guangdong China (Mainland)
  • Usage: Light, Industry, Construction, Digital Products, Vehicle, LED Strip
  • Driving Method: LED Constant Current
  • Certification: TUV, CE, UL, RoHS, ISO9001, CCC
  • Modulation System: PWM
  • Power Supply Voltage: AC85-265
  • Brand: Meanwell
  • Trademark: Meanwell
  • Specification: Universal
  • HS Code: 8504401400
Product Description
OriginaOriginal Meanwell HLG-600H Series Single Output Waterproof IP67 LED Driver Features:

1.Universal AC input / Full range (up to 305VAC)
2. Built-in active PFC function
3. No load power consumption <0.5W at remote OFF
4. High efficiency up to 96%
5. -40ºC ~ +70ºC wide operating range
6. Protections: Short circuit / Over current / Over voltage/ Over temperature
7. Fanless design, cooling by free air convection


Original Meanwell HLG-600H Series Single Output Waterproof IP67 LED Driver Specifications:
 
MODELHLG-600H-12HLG-600H-15HLG-600H-20HLG-600H-24HLG-600H-30HLG-600H-36HLG-600H-42HLG-600H-48HLG-600H-54
OUTPUTDC VOLTAGE12V15V20V24V30V36V42V48V54V
CONSTANT CURRENT REGION Note.46 ~12V7.5 ~ 15V10 ~ 20V12 ~ 24V15 ~ 30V18 ~ 36V21 ~ 42V24 ~ 48V27 ~ 54V
RATED CURRENT40A36A28A25A20A16.7A14.3A12.5A11.2A
RATED POWER480W540W560W600W600W601.2W600.6W600W604.8W
RIPPLE & NOISE (max.) Note.2150mVp-p150mVp-p150mVp-p150mVp-p200mVp-p250mVp-p250mVp-p250mVp-p350mVp-p
VOLTAGE ADJ. RANGE Note.610.2 ~ 12.6V12.7 ~ 15.8V17 ~ 21V20.4 ~ 25.2V25.5 ~ 31.5V30.6 ~ 37.8V35.7 ~ 44.1V40.8 ~ 50.4V45.9 ~ 56.7V
CURRENT ADJ. RANGECan be adjusted by internal potentiometer A type only
20 ~ 40A18 ~ 36A14 ~ 28A12.5 ~ 25A10 ~ 20A8.3 ~ 16.7A7.1 ~ 14.3A6.2 ~ 12.5A5.6 ~ 11.2A
VOLTAGE TOLERANCE Note.3±3.0%±2.0%±1.5%±1.0%±1.0%±1.0%±1.0%±1.0%±1.0%
LINE REGULATION±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%
LOAD REGULATION±2.0%±1.5%±1.0%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%
SETUP, RISE TIME        Note.8500ms, 80ms at full load 230VAC /115VAC
HOLD UP TIME (Typ.)15ms at full load 230VAC /115VAC
INPUTVOLTAGE RANGE        Note.590 ~ 305VAC    127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz
POWER FACTOR (Typ.)PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
TOTAL HARMONIC DISTORTIONTHD< 20% when output loading>=50% at 115VAC/230VAC input and output loading>=75% at 277VAC input
EFFICIENCY230VAC92%93.5%94.5%95%95%95.5%96%96%96%
277VAC92.5%93.5%94.5%95%95%95.5%96%96%96%
AC CURRENT (Typ.)7A / 115VAC    3.3A / 230VAC    2.9A / 277VAC
INRUSH CURRENT(Typ.)COLD START 70A(twidth=1000μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A1 unit (circuit breaker of type B) / 2 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.75mA / 277VAC
PROTECTIONOVER CURRENT           Note.495 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUITConstant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE13 ~ 16V16.5 ~ 20.5V22 ~ 26V26 ~ 30V32.5 ~ 36.5V39.5 ~ 43.5V46 ~ 50V52.5 ~ 56.5V59 ~ 63V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATUREShut down o/p voltage, re-power on to recover
FUNCTIONREMOTE ON/OFF CONTROLPower on : "Hi" >2 ~ 5V or Open circuit  Power off : "Low" <0 ~ 0.5V or Short circuit
5V STANDBY5VSB : 5V@0.5A ; tolerance ±5%, ripple : 100mVp-p(max.)
ENVIRONMENTWORKING TEMP.-40 ~ +70ºC (Refer to "Derating Curve")
WORKING HUMIDITY20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY-40 ~ +85ºC, 10 ~ 95% RH
TEMP. COEFFICIENT±0.03%/ºC (0 ~ 60ºC)
VIBRATION10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY &
EMC
(Note 9)
SAFETY STANDARDS   Note.7UL60950-1, UL8750(type"HL"), CSA C22.2 No. 250.13-12, ENEC EN61347-1, EN61347-2-13 independent, EN62384, IP65 or IP67,
J61347-1, J61347-2-13 approved
WITHSTAND VOLTAGEI/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC/ 70% RH
EMC EMISSIONCompliance to EN55015, EN55022(CISPR22) Class B, EN61000-3-2 Class C (>=50% load) ; EN61000-3-3
EMC IMMUNITYCompliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
OTHERSMTBF76.9K hrs min.  MIL-HDBK-217F (25ºC)
DIMENSION280*144*48.5mm (L*W*H)
PACKING3.9Kg; 4pcs/16.6Kg/0.9CUFT
NOTE1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 50%~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. A type only.
7. Safety and EMC design refer to EN60598-1, subject CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to
perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on http://www.meanwell.com)
10. Refer to warranty statement