Basic Info.
Usage
Light, Industry, Construction, Digital Products, Vehicle, LED Strip
Driving Method
LED Constant Current
Certification
TUV, CE, RoHS, ISO9001, CCC
Power Supply Mode
Constant Current Source
Transport Package
Paper Carton
Origin
Guangdong China (Mainland)
Product Description
OriginaOriginal Meanwell HLG-80H Series Single Output Waterproof IP67 LED Driver Features:
1. Universal AC input / Full range (up to 305VAC)
2. Built-in active PFC function
3. Protections: Short circuit / Over current / Over voltage / Over temperature
4. Cooling by free air convection
5. OCP point adjustable through output cable or internal potentiometer
6. IP67 / IP65 design for indoor or outdoor installations
7. Class 2 power unit
8. Three in one dimming function (1~10Vdc or PWM signal or resistance)
9. Suitable for LED lighting and moving sign applications
10. Compliance to worldwide safety regulations for lighting
11. Suitable for dry / damp / wet location
12. 7 years warranty (Note.10)
Original Meanwell HLG-80H Series Single Output Waterproof IP67 LED Driver Specifications:
MODEL | HLG-80H-12 HLG-80H-15 | HLG-80H-20 | HLG-80H-24 | HLG-80H-30 | HLG-80H-36 | HLG-80H-42 | HLG-80H-48 | HLG-80H-54 |
OUTPUT | DC VOLTAGE | 12V 15V | 20V | 24V | 30V | 36V | 42V | 48V | 54V |
CONSTANT CURRENT REGION Note.4 | 7.2 ~12V 9 ~ 15V | 12 ~ 20V | 14.4 ~ 24V | 18 ~ 30V | 21.6 ~ 36V | 25.2 ~ 42V | 28.8 ~ 48V | 32.4 ~ 54V |
RATED CURRENT | 5A 5A | 4A | 3.4A | 2.7A | 2.3A | 1.95A | 1.7A | 1.5A |
RATED POWER | 60W 75W | 80W | 81.6W | 81W | 82.8W | 81.9W | 81.6W | 81W |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | 200mVp-p |
VOLTAGE ADJ. RANGE Note.6 | 10.8 ~ 13.5V 13.5 ~ 17V | 17 ~ 22V | 22 ~ 27V | 27 ~ 33V | 33 ~ 40V | 38 ~ 46V | 43 ~ 53V | 49 ~ 58V |
CURRENT ADJ. RANGE | Can be adjusted by internal potentiometer A type only |
3 ~ 5A | 3 ~ 5A | 2.4 ~ 4A | 2.04 ~ 3.4A | 1.62 ~ 2.7A | 1.38 ~ 2.3A | 1.17 ~ 1.95A | 1.02 ~ 1.7A | 0.9 ~ 1.5A |
VOLTAGE TOLERANCE Note.3 | ±2.5% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
LOAD REGULATION | ±2.0% | ±1.5% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
SETUP, RISE TIME Note.8 | 1200ms,80ms/115VAC 500ms,80ms/230VAC at full load ; B type 1200ms,200ms/115VAC 500ms,200ms/230VAC at 95% load |
HOLD UP TIME (Typ.) | 16ms at full load 230VAC /115VAC |
INPUT | VOLTAGE RANGE Note.5 | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz |
POWER FACTOR (Typ.) | PF>0.96/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve) |
TOTAL HARMONIC DISTORTION | THD< 20% when output loading>=60% at 115VAC/230VAC input and output loading>=75% at 277VAC input |
EFFICIENCY (Typ.) | 88% | 89% | 90% | 90.5% | 91% | 91% | 91% | 91% | 91% |
AC CURRENT (Typ.) | 0.85A / 115VAC 0.425A / 230VAC 0.4A / 277VAC |
INRUSH CURRENT (Typ.) | COLD START 70A(twidth=485μs measured at 50% Ipeak) at 230VAC |
MAX. No. of PSUs on 16A | 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC |
LEAKAGE CURRENT | <0.75mA / 277VAC |
PROTECTION | OVER CURRENT Note.4 | 95 ~ 108% |
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
SHORT CIRCUIT | Hiccup mode, recovers automatically after fault condition is removed |
OVER VOLTAGE | 14 ~ 17V | 18 ~ 24V | 23 ~ 30V | 28 ~ 35V | 35 ~ 43V | 41 ~ 49V | 48 ~ 58V | 54 ~ 63V | 59 ~ 68V |
Protection type : Shut down o/p voltage, re-power on to recover |
OVER TEMPERATURE | Shut down o/p voltage, re-power on to recover |
ENVIRONMENT | WORKING TEMP. | -40 ~ +70ºC (Refer to "Derating Curve") |
WORKING HUMIDITY | 20 ~ 95% RH non-condensing |
STORAGE TEMP., HUMIDITY | -40 ~ +80ºC, 10 ~ 95% RH |
TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 60ºC) |
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes |
SAFETY & EMC | SAFETY STANDARDS Note.7 | UL8750(type"HL"), CSA C22.2 No. 250.0-08(except for HLG-80H-48/54V & HLG-80H-48/54BL), UL8750 listed for HLG-80H-XBL EN61347-1, EN61347-2-13 independent, J61347-1, J61347-2-13, IP65 or IP67 approved ; Design refer to UL60950-1, TUV EN60950-1 |
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC/ 70% RH |
EMC EMISSION | Compliance to EN55015, EN61000-3-2 Class C (>=60% load) ; EN61000-3-3 |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria B |
OTHERS | MTBF | 357.8Khrs min. MIL-HDBK-217F (25ºC) |
DIMENSION | 195.6*61.5*38.8mm (L*W*H) |
PACKING | 0.84Kg; 16pcs/14.4Kg/0.54CUFT |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Please refer to "DRIVING METHODS OF LED MODULE". 5. Derating may be needed under low input voltages. Please check the static characteristics for more details. 6. A type only. 7. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18. 8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 10. Refer to warranty statement. 11. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains. |
Address:
91, Jinxiu Danfeng Court, No. 1 Biyuan Road, Tanzhou No. 3 Industrial Zone, Gd. P. R. C, Zhongshan, Guangdong, China
Business Type:
Manufacturer/Factory
Business Range:
Electrical & Electronics, Lights & Lighting, Service
Management System Certification:
ISO 9001
Company Introduction:
Zhuhai Hi-Line Electronics is located in the beautiful coastal city-Zhuhai, China. It is a high-tech R& D enterprise dedicated to developing, producing various innovative LED RGB lighting products, LED power supply and intelligent controllers.
Our main products include LED RGB digital boarder tube, LED digital video tube, LED strip light, LED digital DMX tube, LED power supply and RGB intelligent controllers for LED lights. These products are widely applied in municipal projects, casinos, stage lighting, home decoration etc which have been receiving good reputation among many parts of the foreign markets, such as American and European areas, Middle East and Southeast Asia etc.
We have been in LED field since 2007; We continuously focus on our tenet "Quality, Honest, Innovative and Efficient". With experienced R& D team and advanced equipments, we can offer our customers with the most-innovative, cost-effective and advanced decorative LED lighting products used for events, parties, home decorations, weddings, exhibitions, business, indoor and outdoor applications. There is no doubt that your satisfaction is our priority concert.
We are warmly welcome you to establish win-win commercial partnership with us to exchange valuable information and explore splendid future in the field of LED lighting.